A rare complication of implanted central-venous access devices: catheter fracture and embolization

  • Short Communication
  • Published:
Supportive Care in Cancer Aims and scope Submit manuscript

Abstract

Totally implanted central-venous access devices are frequently used for the administration of chemotherapy or parenteral nutrition. Catheter fracture is a rare complication of these devices, with an estimated rate of 0.1%. We have lately seen three cases of catheter fracture with embolization of a catheter fragment to the heart and pulmonary vessels. These cases are described in this article. Catheter fracture is caused by intermittent compression of the catheter between the clavicula and the first rib, which can occur when the catheter has been inserted too far medially. When, on an X-ray of the chest, the catheter is shown to be compressed at the point where the clavicula crosses the first rib, or when infusion through the device suddenly becomes difficult, the chance of catheter fracture is high and the device should be removed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

References

  1. Barrios CH, Zuke JE, Blaes B, Hirsch JD, Lyss AP (1992) Evaluation of an implantable venous access system in a general oncology population. Oncology 49:474–478

    Google Scholar 

  2. Brothers TE, Moli LK von, Niederhuber JE, Roberts JA, Walker-Andrews S, Ensminger WD (1988) Experience with subcutaneous infusion ports in three hundred patients. Surg Gynecol Obstet 166:295–301

    Google Scholar 

  3. Franey T, DeMarco LC, Geiss AC, Ward RJ (1988) Catheter fracture and embolization in a totally implanted venous access catheter. J Parenter Enter Nutr 12:528–530

    Google Scholar 

  4. Grannan KJ, Taylor PH (1990) Early and late complications of totally implantable venous access devices. J Surg Oncol 44:52–54

    Google Scholar 

  5. Hem KG van der, Meijer S, Werter CJPJ, Groeningen CJ van (1991) Spontaneous catheter fracture and embolization of a totally implanted venous access port. Neth J Med 38:262–264

    Google Scholar 

  6. Hinke DH, Zandt-Statsny DA, Goodman LR, Quebbeman EJ, Krzywda EA, Andris DA (1990) Pinch-off syndrome: a complication of implantable subclavian venous access devices. Radiology 177:353–356

    Google Scholar 

  7. Inoue Y, Nezu R, Nakai S, Takagi Y, Okada A (1992) Spontaneous partial fracture of the catheter of a totally implantable subcutaneous infusion port. J Parenter Enter Nutr 16:75–77

    Google Scholar 

  8. Lafrenière R (1991) Indwelling subclavian catheters and a visit with the “pinched-off sign”. J Surg Oncol 47:261–264

    Google Scholar 

  9. Lokich JL, Bothe A, Jr, Benotti P, Moore C (1985) Complications and management of implanted venous access catheters. J Clin Oncol 3:710–717

    Google Scholar 

  10. Noyen J, Hoorntje J, Langen Z de, Leemslag J-W, Sleijfer D (1987) Spontaneous fracture of a totally implantable venous access port: case report of a rare complication. J Clin Oncol 5:1295–1299

    Google Scholar 

  11. Prager D, Hertzberg RW (1987) Spontaneous intravenous catheter fracture and embolization from an implanted venous access port and analysis by scaning electron microscopy. Cancer 60:270–273

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Debets, J.M.H., Wils, J.A.M.J. & Schlangen, J.T. A rare complication of implanted central-venous access devices: catheter fracture and embolization. Support Care Cancer 3, 432–434 (1995). https://doi.org/10.1007/BF00364987

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00364987

Key words

Navigation